Chronological offset of channels in relation to each other (remedied from V1.3)

Rectified from:
Global Drive Oscilloscope V1.3.0.0

Behaviour of the new version?
The channels of a measurement are not chronologically offset in relation to each other.



What does the reaction look like?
The channels of a measurement are chronologically offset in relation to each other.

When does the problem occur?
If additional channels (variables) are integrated after the value in the Position field is altered, these new channels are chronologically offset by the value in the Position field.

Affects which products?
Global Drive Oscilloscope V1.2

Diagnostic possibilities?
None.

Short-term measures/recommendations?
When inserting new channels, make sure that the value set in the Position field is 0.

Evaluation:
Due to the functional restriction described above, the channels of a measurement can be chronologically offset in relation to each other. In this case, the measurement is unusable.

URL for linking this AKB article: /en-de/go/akb/200904396/1/