Corrected from: PLC Designer V3.12
Response of the new version:
If the version of the controller used in the PLC project differs from the version of the actual controller, the following dialog will be indicated when going online:
Selected 'xxx' target system does not correspond to connected 'xxx' device.
After confirming this dialog, you can continue working with the PLC Designer.
What happens?
The PLC Designer does not respond anymore.
When does this behaviour occur?
If the version of the controller used in the PLC project differs from the version of the actual controller, the following dialog is indicated when going online:
Unknown version of application 'Application' on target. Do you want to perform a download and replace the application?
When clicking the <Details> button in this dialog, the PLC Designer no longer responds.
Which products are affected?
PLC Designer V3.3
Possible diagnostics:
None
Short-term measures/recommendations:
Do not use the <Details> button when using different controller versions.
Evaluation:
The PLC Designer may crash if the <Details> button is pressed in a dialog which informs about an unknown application.