Device parameter tab is not online (corrected from V3.10)

?Corrected from:
PLC Designer V3.10

Response of the new version:
If the PLC Designer is online with the controller, the values on the device parameter tabs will be updated.
 
 
What happens?
Although the PLC Designer is online with the controller, the values on the device parameter tabs are not updated.

When does the problem occur?
The above-described response can occur when opening the device parameter tab.

Which products are affected?
PLC Designer from V3.3

Possible diagnostics:
Check if the fields indicating the parameter values are highlighted in yellow.

Short-term measures/recommendations:
Close the tab and go offline/online with the PLC Designer.
If the oscilloscope is used intensively, switch the controller off and on again, if necessary.

Evaluation:
When opening the device parameter tab (e.g. for the i700 servo inverter), the parameter values of the device are not indicated.

URL for linking this AKB article: /en-de/go/akb/201208260/1/