Corrected from: PLC Designer V3.12
Response of the new version:
When copying an i700 to another PLC project, the parameter set of the i700 will be copied as well. The parameter set of the copied i700 will not be reset to the default settings.
What happens?
All parameters of the i700 servo inverter are reset to the default settings.
When does the problem occur?
When copying an i700 to another PLC project, the parameter set of the i700 copy is reset to the default settings.
Which products are affected?
PLC Designer V3.3 and higher
Possible diagnostics:
None
Short-term measures/recommendations:
- Export the parameter set of the i700 servo inverter to a file. For this, select the servo inverter and click the menu items Project>Device parameters>Export device parameters.
- Then copy the i700 to the new project.
- Select the menu items Project>Device parameters>Import device parameters and import the parameter set file created above to the copied i700.
Evaluation:
When copying an i700 servo inverter from one PLC project to another, all parameters of the copy are reset to the default settings. The above-described recommendation provides a workaround for the function restriction.