Exception in PLC Designer when closing or changing a tab in the case of an existing online connection (eliminated from PLC Designer V3.5.1)

Eliminated from:
PLC Designer V3.5.1
 
Behaviour of the new version:
When closing or changing tabs, no Exception occurs.
 
What happens?
PLC Designer indicates an Exception with the message:
Collection was modified; enumeration operation may not execute

When does the problem occur?
The above-described response occurs if an online connection has been established between PLC Designer and control system and an i700 servo inverter, I/O1000 bus coupler EPM-S110 or EPM-S130 tab is closed or it is quickly changed between tabs of this type.

Which products are concerned?
PLC Designer from V3.5

i700 servo inverter
I/O1000 bus coupler EPM-S110 (CAN open)
I/O1000 bus coupler EPM-S130 (EtherCAT)

Possible diagnostics:
None

Short-term measures/recommendations:
Click <Continue> in the Exception dialog. After this, you can continue working without problems.

Evaluation:
The Exception rarely occurs. The project is not damaged by the Exception. After acknowledging the Exception, you can continue working with the PLC Designer without problems.

URL for linking this AKB article: /en-de/go/akb/201303264/1/