No access to i700 and I/O system 1000 parameters (eliminated from V3.5.1)

Eliminated from:
3200C controller V3.5.1
p500 controller V3.5.1
PLC Designer V3.5.1 (Service Pack 1)

Behaviour of the new version:
The parameters of a connected i700 servo inverter or EPM-S110 and EPM-S130 bus coupler can be easily accessed online by the PLC Designer.



What happens?
Despite an existing online connection between PLC Designer and Lenze controller, the parameters of the i700 servo inverter and the I/O system 1000 EPM-S110 and EPM-S130 bus coupler cannot be accessed. The parameter fields of these devices remain with a white background.

When does the problem occur?
The above-described reaction occurs if the oscilloscope tab of an i700 servo inverter is active when logging on to the controller.

Which products are affected?
C3200C controller from V3.3
p500 controller from V3.3
PLC Designer from V3.3

i700 servo inverter
EPM-S110 (I/O system 1000 CANopen bus coupler)
EPM-S130 (I/O system 1000 EtherCAT bus coupler)

Diagnostics options:
None

Short-term measures/recommendations:
Restart the controller.

Evaluation:
The PLC Designer cannot access the parameters of the above devices if the oscilloscope tab of an i700 was active when logging on to the controller.

URL for linking this AKB article: /en-de/go/akb/201304094/1/