Eliminated from:
PLC Designer V3.6
Behaviour of the new version:
User-defined settings on the "Service Data Object" tab do not change after updating the CAN slave.
What happens?
After CAN bus initialisation, the parameter settings of the CAN slave are not as expected.
When does the behaviour occur?
By updating a CAN slave in the device tree of the PLC Designer project, the parameters on the "Service Data Object" tab are reset to their standard settings, i.e. user-defined settings, if any, will get lost.
Which products are concerned?
PLC Designer from V3.0
Short-term measures:
Avoid unnecessary updates of CAN slaves.
If an update is required, check the parameter values on the "Service Data Objects" tab after the update and correct them, if necessary.
Evaluation/recommendations:
Due to this function restriction, the connected CAN slave will not be set to the user-defined parameter values and will not respond as expected during CAN bus initialisation.