Corrected from:
PLC Designer V3.8
Response of the new version:
Projects using the application template and created with older PLC Designer versions can be compiled correctly with PLC Designer V3.8.
What happens?
Projects using the application template cannot be properly compiled.
When does this behaviour occur?
Projects using the application template and created with PLC Designer V3.3.2 cannot be compiled correctly if they are opened with a higher PLC Designer version.
Which products are affected?
PLC Designer from V3.3
Short-term measures/recommendations:
Go to the PLC project and change the L_EATP_ApplicationTemplate library version to version V3.3.2.1.
Evaluation:
PLC projects containing the application template and created with older PLC Designer versions cannot be properly compiled. To remove the function restriction, change the L_EATP_ApplicationTemplate library version.