?Corrected from:
VisiWinNET 6.5 SP5.
Response of the new version:
Existing texts and comments are not overwritten when browsing.
What happens?
The symbol configuration of the PLC has been browsed. The symbol configuration includes structures.
Structural elements have been declared as a recipe.
To be displayed in "RezeptListView" control, for every structure element a text was defined in language switching.
When does this behaviour occur?
After reading the symbol configuration again, all texts that have been defined for structural elements are no longer available.
Texts for items which are not defined in a structure are not deleted.
Which products are affected?
- VisiWinNET Smart and Professional (detected in V6.5.4.1).
Short-term measures:
None
Evaluation/recommendations:
If possible, browse structures as individual variables.
Already existing structures with the same variables must first be deleted.