Corrected from:
PLC Designer V3.18
Response of the new version:
When opening the 'Manual control' dialog (previously 'Manual motor direction of rotation check') or opening the controller logbook or the logbook of a drive, ongoing trace recording processes are continued.
What happens?
Trace recording started in the PLC Designer stops.
When does this behaviour occur?
Trace recording started in the PLC Designer stops ...
or
- ... if the 'Logbook' dialog of the controller or a drive is opened.
After closing the dialog, tracing can be started again.
Which products are affected?
PLC Designer 3.3.2
Short-term measures:
Use the EASY Starter to open the 'Manual motor direction of rotation check' or the 'Logbook' dialog to ensure that running tracing processes are not stopped.
Evaluation/recommendations:
Opening dialogs in the PLC Designer may stop trace recording started in the PLC Designer.