Declaration dialog opens although the entered variable has already been declared (corrected from V3.18)

?Corrected from:
PLC Designer V3.18
 
Response of the new version:
When entering a variable in the editor which is an element of a structure that is instantiated in an array, the declaration dialog does not open.
 
What happens?
The declaration dialog opens although the entered variable has already been declared.
 
When does this behaviour occur?
The behaviour occurs if a variable which is an element of a structure that is instantiated in an array is entered in the editor.
 
Which products are affected?
PLC Designer from V3.0 
 
Short-term measures:
Close the declaration dialog or deactivate the 'Declare unknown variables automatically (AutoDeclare)' option  in the Options dialog (menu Tools > Options) in the category 'SmartCoding'.
 
Evaluation/recommendations:
When entering a structure element from an array (ARRAY OF STRUCT), the declaration dialog for declaring the variable opens. As an applicative solution, deactivate the PLC Designer's AutoDeclare function (see 'Short-term measures').

URL for linking this AKB article: /en-de/go/akb/201600550/1/