New element Analog clock in the "Date/time control elements" tab
The analog clock can display both the system time of the PC and the time of a TOD variable.
New property in the Line element ("Base" tab)
Absolute movement\Interior rotation: Rotation of the line around the centre in angular degrees (c300 and p300 only)
New properties in the Bar display element ("Measuring devices" tab)
Background\Own image: You can save any graphics as bar display background
Bar\Optimum size for bar: Changes the width of the bar
State variables\Invisible: Makes the bar display invisible
New properties in the Potentiometer element ("Measuring devices" tab)
Background\Own image: You can save any graphics as potentiometer background
Colors\Color areas\Use color areas for scale: With this setting, you select the colors of the color areas for the scale and their frames
State variables\Deactivate inputs: If this property is active, the element does not respond to inputs
New properties in the Alarm table element ("Alarm manager" tab)
Selection\Variable for selected row: Index of the selected row
Selection\Variable for valid row selection: Validity of the selected row
Control variables\Count alarms: Number of displayed alarms
Control variables\Count visible rows: Number of rows visible in the alarm table
Control variables\Current scroll index: Index of the first visible row of the alarm table
In the Trace and Trend elements ("Special control elements" tab), you can set the line width and the line style (e.g. Solid, Dashes,...) for the individual curves/variables.