L_TT1P_TechnologyModules_LM V3.14.0.21 library cannot be opened

?Corrected from:
L_TT1P_TechnologyModules_LM library V3.14.1.41
 
Response of the new version:
L_TT1P_TechnologyModules_LM library V3.14.1.41 replaces version 3.14.0.21. You can use the EASY Package Manager to install the 'Libraries>PLC Designer 3.x>Libraries V3.14.0 (1.1)' library package containing the new library version.
To use the new library version in your PLC project, open the Library Manager in the PLC Designer. Click the <Placeholder> button in the Library Manager. Right-click 'L_TT1P_TechnologyModules_LM' in the 'Library' column in the 'Placeholder' dialog. Confirm the 'Placeholder' dialog with <OK>.
 
What happens?
The following error message appears when opening a PLC project:
One or several libraries of the project could not be loaded. More details are provided in the message window.
 
The following message appears in the message window:
The '#L_TT1P_TechnologyModules' library could not be opened. (Reason: The 'L_TT1P_TechnologyModules_LM, 3.14.0.21 (Lenze)' library is not installed.) 
 
When does this behaviour occur?
Lenze has blocked L_TT1P_TechnologyModules_LM library version 3.14.0.21 and no longer provides the library via the EASY PackageManager. Depending on which library package version has been installed with the EASY Starter, the library will not be available in the Library Repository of the PLC Designer. 
 
Which products are affected?
PLC Designer from V3.14
L_TT1P_TechnologyModules_LM library V3.14.0.21
 
Short-term measures:
Contact the Lenze Service.
 
Evaluation/recommendations:
Due to a function restriction in the L_TT1P_TechnologyModules_LM library, library version V3.14.0.21 is no longer published by Lenze. The above-described error message appears if the library has not been installed in the PLC Designer.

URL for linking this AKB article: /en-de/go/akb/201700031/1/