Project from project archive cannot be translated without errors

What happens?
The following error messages appear when translating a project:
  • Parameter set file for field device 'xxx' could not be created. Device description is incomplete. Start the L-foce Package Manager and install missing description.
  • Firmware file 'xxx' for device 'xxx' is missing. Please execute the Lenze package manager.
When does the behaviour occur?
If a project archive is extracted with PLC Designer (menu command 'File' > 'Project archive' > 'Extract archive') and there are fieldbus devices in the project, e.g. i5xx, i950, i700 or c5xx, whose firmware and parameter description files have not yet been installed on the PC via the EASY Package Manager, the translation errors described above occur.
 
Which products are affected?
PLC Designer V3.0
Short-term measures: 
Install the missing firmware and parameter description files in the EASY Package Manager.
 
Evaluation / Recommendations:
The PLC Designer does not automatically save the firmware and parameter descriptions of the fieldbus devices in the archive when a project archive is created. If the archive is extracted on a PC on which these files have not yet been installed with the EASY Package Manager, the project cannot be translated without errors and loaded into the controller.
 
Automatic Translation

URL for linking this AKB article: /en-de/go/akb/201800169/1/