TA SyncAndCorrection: Some errors are not reported (corrected from V01.02.03)

Eliminated from:
TA_i900:    from V01.02.03.0985
 
Behaviour of new version:
In the event of an error, the corresponding error codes are now displayed in parameter 0x5040:114 (Error code).

 
What happens?
Although an error is pending, the technology application reports no error in parameter 0x5040:114 (error code).
 
When does this behaviour occur?
The behaviour occurs when using the technology application and one of the following errors occurs:
Error number (L_IE1P)Error textError cause
?17000?ModuloAxisIsRequiredInstead of a Modulo axis, a linear axis is connected.
?17006?MarkStackLimitReachedThe length of the stacks for the end marks has been exceeded as the distance between touch probe sensor and tool is bigger than the length of the register.
?17110?MasterIsReversingThe master axis changes the direction of rotation.
?17117?CorrectionGreaterCorrWindowThe correction value is greater than the available correction window.
?17170?SyncModeVelAccRequiredSynchronisation to the master axis requires the "Ramp_VelAcc" coupling mode.
?17177?lrMarkDist <= 0 The parameterised mark distance is not permissible. A value <= 0 has been set.
?19503?MaxNrOfTpExceeded_MarkRegisterThe mark stack has exceeded the maximum number of permissible marks.
?20664?Invalid_GearFactorInvalid gearbox factor
?20667?PosInInvalid_AddOffsetCyclicInvalid input position AddOffsetCyclic
 
 
Which products are affected?
TA_i900:

Short-term measures, Evaluation/Recommendations:
 