Error message when displaying the trace cursor (corrected from V3.24)

Corrected from:
PLC Designer V3.24

Response of the new version:
The value of the ENUM variable declared as VAR_IN_OUT is displayed correctly in the trace even if the cursor is shown.
 
What happens?
When displaying a cursor (menu command 'Trace' > 'Cursor') on a trace tab, the error message appears:
Object reference not set to an instance of an object
 
When does the behaviour occur?
The error message occurs when an ENUM variable declared as VAR_IN_OUT is used in a trace.
 
Which products are affected?
PLC Designer from 3.20
 
Short-term measures:
Do not use an ENUM variable declared as VAR_IN_OUT in a trace.
 
Evaluation/Recommendations:
With occurrence of this function restriction the PLC Designer project is neither corrupt nor damaged.

Automatic Translation

URL for linking this AKB article: /en-de/go/akb/202000196/1/