Startup parameters of an EtherCAT slave cannot be changed

Corrected from:

Response of the new version:

What happens?
The parameters on the 'Startup Parameters' tab of a unit cannot be changed. Although a dialogue for setting the values opens when double-clicking on a start parameter or by clicking on <Edit> and the values can also be changed there, it is not possible to confirm this dialogue with <OK> so that the changed values are accepted.

When does the behaviour occur?
The behaviour occurs when the start parameters of an EtherCAT slave are edited.
 
Which products are affected?
PLC Designer from V3.24

Short-term measures:
After opening the dialogue for editing a startup parameter, first select an entry from the object dictionary (the list in the upper part of the dialogue). Then you can change the values in the fields Name, Index, Subindex, Bit length and Value. With <OK> the selected startup parameter is changed.
 
Evaluation / recommendations:
After the controller is switched to mains, it transfers the values from the startup parameter list to the respective devices and parameters (e.g. 9400) via EtherCAT. Due to this functional restriction, changing the startup parameters is only possible via the procedure described under Short-term measures.

Automatic Translation

URL for linking this AKB article: /en-de/go/akb/202200138/1/