Error message when compiling in simulation mode

?Corrected from:
-

Response of the new version:
-
 
What happens? 
The following error messages occur when compiling in simulation mode:
  • C0046:  Identifier 'uiPacketSize' not defined
  • C0018:  'uiPacketSize' is no valid assignment target
When does the behaviour occur?
The behaviour occurs when compiling with controller types c300, p300, 3200C, p500 or 3241C with existing network variable lists in simulation mode, e.g. when logging in.
 
Which products are affected?
PLC Designer

Short-term measures: 
Remove the network variable lists from the project for using the simulation mode.
 
Evaluation / recommendations:
The function restriction only occurs if the simulation mode (menu 'Online' > 'Simulation') has been activated in the PLC Designer.


Automatic Translation

URL for linking this AKB article: /en-de/go/akb/202200237/1/