Oscilloscope recording cannot be uploaded from i550 (corrected from V3.26)
?Corrected from:
PLC Designer V3.26
Response of the new version:
With the current version of the PLC Designer an oscillogram created in the Frequency Inverter i550 can be uploaded without errors.
What happens?
When uploading an oscillogram created in the Frequency Inverter i550 with the PLC Designer, the error message appears:
Upload of the oscillogram failed
When does the behaviour occur?
The behaviour occurs when an oscillogram created on the i550 is uploaded with the PLC Designer via the Lenze controller as gateway.
Which products are affected?
PLC Designer from V3.24
Cabinet Controller c300
Cabinet Controller 3200C
Panel Controller p300
Panel Controller p500
Frequency Inverter i550
Short-term measures:
Use the EASY Starter to upload the oscillogram.
Evaluation / recommendations:
Due to this functional restriction, no oscilloscope recording can be uploaded from the Frequency Inverter i550 with the PLC Designer. The EASY Starter must be used for this purpose.