Compilation error in i950 standard project: 'Unknown type: 'L_IMHP_ModuleHandler'
Corrected from:
-
Behavior of the new version:
-
Description of the behavior: After creating a new PLC project for a Servo Inverter i950 V1.10 with the project template 'Standard project', error messages appear when compiling the project, including:
Unknown type: 'L_IMHP_ModuleHandler'
Conditions under which the behavior occurs: The error message described above occurs because the wrong compiler version V3.5.9.50 was preselected when the project was created.
Affected products: PLC Designer from V3.28
Servo Inverter i950 BS-STO and ES with version V1.10
Short-term measures, Recommendations, Rating:
Make sure that compiler version V3.5.17.40 is set in the 'New project' wizard when creating a PLC project for a Servo Inverter i950 V1.10.
If the PLC project has already been created, set compiler version V3.5.17.40 in the 'Compile options' category in the 'Project settings' dialog (menu 'Project' > 'Project Settings').
Alternatively, you can also enter this setting via the 'Project environment' dialog (menu 'Project' > 'Project environment').